Chapter 4 Department of Defense Unique Identification (UID)
4-4 HawkEye™ 45T User Manual Rev 2.0.0, Jan 2009
The following options apply to all symbologies:
• UII/CPN On for All Symbologies — The HE45T is configured to construct
UII/CPN/LBN for all symbologies. For decoded symbologies without valid
UII/CPN/LBN, the HE45T stops image acquisition without an output string.
• UII/CPN Off — The HE45T is back to normal decoder behavior without
constructing UII/CPN/LBN.
FIGURE 4–1. UII Codes
Output Format: UII/CPN; DF0; DF1; DF2; DF3; DF4; DF5; DF6; DF7
– DF1 - DF7: The fields display data elements:
• If there are less than seven data elements, an empty string is filled
in at the end.
• If there are more than seven elements, only first seven elements
are displayed.
– There is a space between UII and CPN in both tables (UII:12345678
CPN:87654321).
– The constructed UII type can be Contruct_1, Contruct_2,
Construct_1_2, or IUID_EQUIVALENT.
– The constructed CPN type can be PNR, 30P, or 240. The constructed
LBN type is 30T.
UII/CPN DM On
UII/CPN Off
UII/CPN DM with Data Field
UII/CPN On for All Symbologies