Step 2 — Connect the System
Connecting by RS-232 / RS-422 / RS-485
Connect the imager (1) to the IB-131/IC-332 interface (2) and (3).
Connect the communication cable (6) to the host, and to the host port
on the IB-131.
Connect the object detector (5) to the IB-131.
Connect the power supply (4) to the IB-131.
Apply power to the imager.
Hardware Configuration
Caution:
Be sure that all cables are connected
BEFORE
applying power
to the system. Always power down
BEFORE
disconnecting any cables.
Scanner
Network
Host
1
2
3
6
4 5
Step 1 — Check Hardware
Item Description Part Number
1 Quadrus MINI Series Imagers FIS-6300-XXXXG
2 IC-332 Adapter FIS-0001-0035G
3 IB-131 Interface Box 99-000018-01
4 Power Supply
97-100004-15 (90-264 VAC, 24VDC, USA/Euro plug)
5 Object Detector 99-000017-01
6 Communication Cable 61-300026-03
Scanner
Network
Host
1
2
3
6
4 5
Caution: Be sure that all cables are connected BEFORE applying power
to the system. Always power down BEFORE disconnecting any cables.
Hardware Required
Quick Start Guide
Quadrus MINI
Series
P/N 83-116302 Rev B
Step 3 — Position Imager
Place the imager and test symbol in a location with as little ambient light
as possible.
Position the imager at a focal distance between
2”
and
6” from the symbol
.
Tip the imager relative to the symbol to avoid glare from specular reflection.
Avoid excessive skew or pitch. Maximum skew is
±30°
; maximum pitch is
±30°
).
Symbols can be rotated (tilted) at any angle; however, for best results
symbols should be aligned with the FOV (field of view). In the case of linear
symbols, aligning the bars in the direction of their movement (“ladder”
orientation) will minimize the chances of blurring and No Reads.
Imager / Symbol Positioning
Step 4 — Install ESP
ESP Software can be found on the Microscan Tools CD that is packaged with
the MINI Hawk.
1. Follow the prompts to install ESP from the CD.
2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at
www.microscan.com.
Refer to the MINI Hawk High Performance Imager User’s Manual for detailed
information about using ESP to configure the MINI Hawk.
Step 5 — Select Model
When you start ESP, this menu will appear:
1. Click the button showing the imager used in your application.
2. Click OK.
Note: You can also simply double-click the button showing your
imager to make your selection.
3. Click Yes when this dialog appears:
Note: If you need to select another model later, click the Switch
Model button near the top of the screen or use Model > New
Model in the menu toolbar.
Page view 0
1 2

Summary of Contents

Page 1 - Quadrus MINI

Copyright ©2009 Microscan Systems, Inc. Step 2 — Connect the SystemConnecting by RS-232 / RS-422 / RS-485• Connect the imager (1) to the IB-131/IC-3

Page 2

Copyright ©2009 Microscan Systems, Inc.Step 6 — ConnectTo connect using the Connection Wizard:• Click Connect on the menu toolbar, and then select Con

Comments to this Manuals

No comments