Microscan MS-4 Specifications Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
Response Timeout
3-10 MS-3 Laser Scanner User’s Manual
3–Protocol
Response Timeout
Definition: Time the scanner will wait before timing out if ACK, NAK, and ETX are
enabled, and a host response is expected.
Usage: Only used when a response is required from the host. While in Multi-
drop, if the scanner does not receive an ACK or NAK from the host
after sending polled data, it will act on a fault. The scanner can be set
to wait indefinitely by setting Response Timeout to zero.
Serial Cmd: <K143,response timeout>
Default: 0 (causes an indefinite wait.)
Options: 0 to 65000 (0 to 65 seconds)
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 201 202

Comments to this Manuals

No comments