Chapter 4 Read Cycle/Trigger
MS-3 Laser Scanner User’s Manual 4-13
4–Read Cycle/Trig-
End Serial Trigger Character (non-delimited)
Note: Serial Data or Serial Data or Edge triggering mode must be enabled for
Serial Trigger Character to take effect.
Definition: A single ASCII host serial trigger character that ends the read cycle and
is not enclosed by delimiters such as < and >.
Usage: It is useful in applications where different characters are required to
start and end a read cycle.
Serial Cmd: <K230,end trigger character>
Default: Null (disabled)
Options: Two hex digits representing an ASCII character except <, >, XON and
XOFF.