MS-2 CCD Reader User’s Manual 4-15
Read Cycle
No Read Message
Note: A No Read message can only be transmitted when in Single symbol mode and no
decodes occur.
No Read Status
No Read Message
Note:
A
No Read
message is not output when the reader is disabled (when an
<I>
command
has been sent).
Usage: Used in applications where the host needs serial verification that a symbol
has not been read.
Definition: When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No Read message will be transmitted to the host.
Serial Cmd: <K714,status,No Read message>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Any combination of ASCII characters can be defined as the No Read
message.
Serial Cmd: <K714,status,No Read message>
Default: No Read
Options: 1 to 20 ASCII characters.