5-16 MS-2 CCD Reader User’s Manual
Industrial 2 of 5
Symbol Length # 1 (Industrial 2 of 5)
Symbol Length # 2 (Industrial 2 of 5)
Range Modes (Industrial 2 of 5)
Variable Length
To set for any length, Symbol Length # 1 and Symbol Length # 2 must both equal zero.
Minimum Length
To set for minimum length, both Symbol Length # 1 and Symbol Length # 2 must be
equal to each other and be any number other than zero.
Fixed Length
To set for a fixed length, Symbol Length #1 and Symbol Length #2 must not be equal to
each other.
Definition: This field specifies the number of characters that the reader will recognize,
including start and stop characters and check characters. The reader
ignores any symbol with fewer than the specified number of characters.
Because Industrial 2 of 5 is a continuous symbology, it is prone to substitution
errors. Therefore, a symbol length must be defined and a symbol must contain
an even number of characters.
Serial Cmd: <K488,status,check character status,check character output status,format,
symbol length #1,symbol length #2>
Default: 10
Options: 0 to 32
Definition: This field specifies the number of characters that the reader will recognize,
including start and stop characters and check characters. The reader
ignores any symbol with fewer than the specified number of characters.
Because Industrial 2 of 5 is a continuous symbology, it is prone to substitution
errors. Therefore, a symbol length must be defined and a symbol must contain
an even number of characters.
Serial Cmd: <K488,status,check character status,check character output status,format,
symbol length #1,symbol length #2>
Default: 6
Options: 0 to 32