MS-2 CCD Reader User’s Manual 5-11
Symbologies
Code 93
Minimum Symbol Length (Code 93)
Usage: Used in some clinical applications.
Definition: Code 93 is a variable-length, continuous symbology employing four element
widths. Each Code 93 character has nine modules that may be either black
or white. Each character contains three bars and three spaces.
Serial Cmd: <K475,status,0,minimum symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Specifies the minimum number of characters that the reader will recognize,
not including the start and stop check characters. The reader ignores any
symbol smaller than the specified length.
Note: When setting Minimum Symbol Length to any value other than 0,
add 1 to account for a reserved space. For example, if your symbol has 3
characters, set Symbol Length to 4.
Serial Cmd: <K475,status,0,minimum symbol length>
Default: 10
Options: 0 to 32