5-6 MS-2 CCD Reader User’s Manual
Codabar
Codabar
Start/Stop Output Status (Codabar)
Symbol Length Status (Codabar)
Usage: Used in photo-finishing and library applications. Previously used in medical
applications, but not typically used in newer medical applications.
Definition: Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, .,
+, and ) with start/stop codes and at least two distinctly different bar
widths.
Serial Cmd: <K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
When enabled, the start and stop characters will be present in the data output
of the decoded symbol.
When disabled, the start and stop characters will not be present in the data
output of the decoded symbol.
Note: Because the start and stop characters are included as part of the
data, the characters must be included as part of the length in a fixed length
mode of operation.
Serial Cmd: <K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: When set to Any/Minimum, any symbol length is considered valid.
When set to Fixed, the reader will check the symbol length against the
Symbol Length Status parameter.
Serial Cmd: <K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default: Any/Minimum
Options: 0 = Any/Minimum 1 = Fixed