Microscan MS-4 Specifications Page 104

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 103
Matchcode Type
6-10 MS-3 Laser Scanner User’s Manual
6–Matchcode
Sequence On Mismatch
Note: Matchcode must be set to Sequential for this command to function.
The scanner will sequence the master to one more/less than the decoded symbol. As
an example of Sequence On Mismatch Enabled, consider the following decodes:
As an example of Sequence On Mismatch Disabled, consider the following
decodes:
Definition: When set to Enabled, the master symbol sequences on every decode,
match or mismatch.
When set to Disabled, the master symbol will not sequence whenever
consecutive mismatches occur.
Usage: Enable this parameter if every trigger event should have a decode and
more than one consecutive mismatch may occur.
Disable this parameter if every trigger event should have a decode but
no more than one consecutive mismatch may occur.
Serial Cmd: <K223,matchcode type,sequential matching,match start position,
match length,wild card character,sequence on noread,sequence on
mismatch>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Master sym-
bol
Decoded symbol Master symbol after decode
001 001 002
002 002 003
003 abc 004 (sequenced on mismatch)
004 004 005
005 def 006 (sequenced on mismatch)
006 ghi 007 (sequenced on mismatch)
007 007 008
Master sym-
bol
Decoded sym-
bol
Master symbol after decode
001 001 002
002 002 003
003 abc 004 (sequenced because of previous match)
004 004 005
005 def 006 (sequenced because of previous match)
006 ghi 006 (not sequenced because of previous mismatch)
006 006 007
Page view 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 201 202

Comments to this Manuals