Symbol Output
8-6 MS-3 Laser Scanner User’s Manual
8–Data Outputs
As Soon As Possible
End of Read Cycle
Note: See “End of Read Cycle Mode” on page 4-15 for options to end the read cycle.
Definition: Enabling As Soon As Possible causes symbol data to be sent to the
host immediately after a symbol has been successfully decoded.
Note: More than one decode might in fact be required to qualify as a
good decode, depending on how Decodes Before Output is set.
Usage: As Soon As Possible is useful in applications in which symbol data
needs to be moved quickly to the host, typically when the host is mak-
ing decisions based on symbol data.
Definition: Enabling End of Read Cycle means that symbol data does not get sent
to the host until the read cycle ends with a timeout or new trigger.
Usage: End of Read Cycle is useful in timing-based systems in which the host
is not ready to accept data at the time it is decoded.
Read cycle Duration
Start of read cycle
End of read cycle
This is when host
expects output
Host
activates trigger
Figure 8-1 Read Cycle