Microscan MS-4 Specifications Page 130

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 129
Message Output
8-8 MS-3 Laser Scanner User’s Manual
8–Data Outputs
Noread Message
Noread Status
Noread Message
Note: Noread Message will only be transmitted if Symbol Output (“Symbol Output
Status” on page 8-4) is set to Match, Mismatch or Good Read.
Noread Message can be set to any ASCII characters except NULL <> and , (comma).
Definition: When enabled, and if no symbol has been decoded before timeout or
the end of the read cycle, the noread message will be transmitted to
the host.
Usage: Used in applications where the host needs serial verification that a sym-
bol has not been read and especially useful in new print verification.
Serial Cmd: <K714,status,noread message>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Any combination of ASCII characters can be defined as the noread
message.
Serial Cmd: <K714,status,message>
Default: NOREAD
Options: 0 to 7 ASCII characters.