Microscan MS-4 Specifications Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
Chapter 5 Symbology
MS-3 Laser Scanner User’s Manual 5-25
5–Symbology
Pharmacode
Note: It is recommended that you disable AGC before enabling Pharmacode.
Pharmacode Status
Fixed Bar Length Status (Pharmacode)
Fixed Bar Length (Pharmacode)
Minimum Number of Bars (Pharmacode)
Definition: The bar code encodes up to five different numbers, each with its own
color which may be entered in decimal or "binary" format with a 1 repre-
sented by a thick bar and a 0 represented by a thin bar. Bar width is
independent of height.
In decimal format, each part can be up to 999999.
In binary format, each input have up to 19 ones and zeros.
Usage: Pharmacode is used mostly with packaging for the pharmaceuticals
industry.
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of
bars,bar widths,forward/reverse>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of
bars,bar widths,forward/reverse>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of
bars,bar widths,forward/reverse>
Default: 10
Options: 5 to 16
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of
bars,bar widths,forward/reverse>
Default: 5
Options: 5 to 16
Page view 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 201 202

Comments to this Manuals

No comments