MS-4X Imager User Manual
6-35
Symbologies
DataBar Limited
Note: DataBar Limited was previously known as “RSS Limited”.
DataBar-14
Note: DataBar-14 was previously known as “RSS-14”.
Usage: DataBar Limited is designed to be read by laser and CCD readers. It is
not recommended for omnidirectional slot scanners.
Definition:
Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
Serial Cmd: <K483,status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Used in the grocery, retail, and prescription drug industries where 14-digit
EAN item identification may be needed.
Definition: DataBar-14 is a fixed symbol length symbology that encodes 14 digits,
including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be
stacked in two rows, it can read omnidirectionally if printed in full height, or
horizontally if height-truncated for small marking.
Serial Cmd: <K482,status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled