MS-4X Imager User Manual
3-19
Communications
Daisy Chain Autoconfigure
Note: All secondary readers must be set to Serial for Daisy Chain to function.
When setting up a daisy chain operation, perform the following steps:
1. Set the primary imager (the one connected to the host) to Serial.
This sets all the imagers in the chain to Serial when the command is executed.
Before Autoconfigure you must set the primary imager to Serial (S):
2. Send <K150DAISY>.
3. If necessary, set the primary imager to Edge.
After
Autoconfigure
you may set the primary imager to
Edge
(
S
), but the other imagers
mus
t remain in
Serial
(
S
):
Usage: For quick setup and configuration of your daisy chain network.
Definition: The command to autoconfigure the daisy chain is sent to the primary
imager and the software responds in the following ways:
Counts the number of secondary readers in the daisy chain.
Assigns an internal ID number (1...n) to each secondary reader, where
the first
secondary reader is number 1 (the primary readers ID being a 0).
Propagates the communications settings and the relevant operating
mod
es of the primary imager to the host and auxiliary ports of each
secondary reader.
Resets each secondary reader.
Confirms that each secondary reader has acquired the new settings.
Serial Cmd: <K150DAISY>
Host
Primary
Imager
Secondary
Imager
Secondary
Imager
SS S
Host
Primary
Imager
Secondary
Imager
Secondary
Imager
ESS
Page view 62