Microscan MS-4X User Manual Page 314

  • Download
  • Add to my manuals
  • Print
  • Page
    / 374
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 313
13-20
MS-4X Imager Us
er Manual
Default/Reset/Save
Customer Default Parameters
Customer default parameters (saved by <Zc>) are the same set of parameters as power-on
parameters but are saved in a different, isolated section of NOVRAM. This allows a user
essentially to create a backup set of parameters that can be recalled in the event that the
current parameters or power-on parameters have been accidentally changed or are no
longer desired.
It is important to note that a hardware default does not affect customer default parameters.
For example, a user that has inadvertently changed communication settings and saved
them with a <Z> command, may not know the correct settings or have the capability to
communicate within those settings. By first doing an EZ button default or hardware default
to restore the known Microscan defaults, the user can then recall the previous customer-
saved settings with an <Arc> or <Zrc> command.
Microscan Default Parameters
Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults
Microscan default parameters can be recalled (loaded into current settings) with <Ard>
command or recalled and saved for power-on with the <Zrd> command.
Hardware Default
If a software default and reset is not possible, it may be necessary to reset the reader by
shorting (connecting) specific pins. This procedure has the same effect as the <Zrd>
software command.
Important: For this reset to occur, this command must be executed within 60 seconds of a
power-on or a reset.
1. Apply power to the reader.
2. If using an IB-131, locate pins 7 and 11 on the host connector
.
Cau
tion: Be certain that the correct pins are located. Connecting the wrong pins coul
d
cause serious damage to the unit.
3. Momentarily connect these wires (or pins) and listen for a series of short beeps.
4. Within 3 seconds, connect them again. A longer beep should be heard. If not, rep
eat
the p
rocess.
Default on Power-On
You can also use the EZ button to default the reader by holding it down while applying
power to the reader, provided that this feature is enabled.
Page view 313
1 2 ... 309 310 311 312 313 314 315 316 317 318 319 ... 373 374

Comments to this Manuals

Vikitpm 04 Jan 2024 | 15:20:38

urenrjrjkvnm

Evapsi 07 Jan 2024 | 00:41:38

Med