1-4
MS-4X Imager Us
er Manual
Position Imager and Symbol
Step 3 — Position Imager and Symbol
Position the imager at a distance from the symbol that matches the factory pre-set focal distance.
For e
xample, if your imager is pre-set at 4”, position the parting line 4” from the symbol.
Tip the imager relative to the symbol to avoid the glare of direct (specular) reflection. The
case p
arting line should be perpendicular to the plane of the symbol by either pitching the
symbol or the imager as shown.
Position the imager in a place with as little ambient light as possible.
Symbols can be rotated (tilted) at any angle; however, for best results symbols shoul
d
be aligned
with the FOV (field of view).
In the case of linear symbols, aligning the bars in the direction of their movement (“ladder”
orient
ation) will minimize the chances of blurring, and will produce better reads.
Important: Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch
is
±30°. The
illustration below shows skew axis, pitch axis, and tilt axis.
Note: For accuracy of testing and performance, Microscan recommends using a mounting
arm adapter kit. Contact your Microscan sales manager for details about mounting arm
adapter kits and other accessories.
Imager and Symbol Orientation
Imager and Symbol Orientation
Skew axis
Tilt
axis
Pitch
axis
Scan line