Microscan MS-4X User Manual Page 176

  • Download
  • Add to my manuals
  • Print
  • Page
    / 374
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 175
7-10
MS-4X Imager Us
er Manual
Output Indicators
Target Pattern
Always OFF
The target pattern will remain OFF at all times unless overridden by the EZ button or
operational command.
ON Only When Not in the Read Cycle
The target pattern is always ON except during the read cycle. If the EZ button or operational
command overrides this setting, the target pattern will remain on at all times.
ON Only When in the Read Cycle
The target pattern will remain OFF except during the read cycle. If the EZ button or operational
command overrides this setting, the target pattern will remain on at all times.
Always ON
The target pattern is always ON.
Usage: Assists users in positioning and locating symbols in the center of the
imager’s field of view.
Definition: The user can control when the targeting system is ON or OFF, and can
save this condition for power-on.
Serial Cmd: <K750,green flash mode,target pattern status,green flash duration>
Default: Always ON
Options: 0 = Always OFF
1 = ON only when not in the read cycle
2 = ON only when in the read cycle
3 = Always ON
Page view 175
1 2 ... 171 172 173 174 175 176 177 178 179 180 181 ... 373 374

Comments to this Manuals

Vikitpm 04 Jan 2024 | 15:20:38

urenrjrjkvnm

Evapsi 07 Jan 2024 | 00:41:38

Med