MS-4 Imager User’s Manual 5-5
Read Cycle
Multisymbol
Number of Symbols
Multisymbol Separator
Note:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K222h,,3C>
For >: <K222h,,3E>
For
, : <K222h,,2C>
See ASCII Character Entry Modifier on page 3-32 for a more detailed explanation of how
to enter ASCII characters as hex values.
Note: If No Read messages are disabled and there are No Reads occurring, separators
will only be inserted between symbol data outputs.
Usage: Multisymbol is commonly used in shipping applications where a shipping
symbol contains individual symbols for part number, quantity, etc. This
feature allows on trigger to pick up all the symbols.
Definition: Multisymbol allows the user to define up to 100 symbols that can be read
in a single read cycle.
Conditions: The following conditions apply:
Each symbol must be different to be read, unless in Rapid Capture
Mode, configured for “triggered capture”.
The maximum number of characters in a read cycle is 3,000 for all
symbols.
All No Read messages are posted at the end of the data string, unless
output filtering is enabled.
If more than one symbol is within the field of view at the same time,
symbol data may not be displayed in the order of appearance.
•If
Matchcode Type
is set to
Sequential
or if
Trigger
is set to
Continuous
Read 1 Output
, the Imager will behave as if
Number of Symbols
were
set to
1
, regardless of the user-defined configuration.
Definition: Number of Symbols is the number of different symbols that can be read in
a single read cycle.
Serial Cmd: <K222,number of symbols, multisymbol separator>
Default: 1
Options: 1 to 100
Usage: Used to delimit or separate data fields with a user defined character.
Definition:
Any valid ASCII character, inserted between each symbol read when Multisymbol
is set to any number greater than 1.
Serial Cmd: <K222,number of symbols,multisymbol separator>
Default: , (comma)
Options: Any available ASCII character.