Microscan MS-4 User Manual Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 390
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
MS-4 Imager User’s Manual 4-15
Calibration
Medium Pass
The theory behind Medium Pass is to develop a readable range from which to dial in a
decoded symbol.
Running Medium Pass
Prog Rating Decode Quality Shutter Gain Locate
51 4216 2 8 250 0 5
53 8436 4 20 250 4 4
55 6336 3 24 250 8 4
57 8448 4 32 250 12 4
59 8456 4 40 250 16 5
61 8464 4 48 250 20 4
63 8472 4 56 250 24 5
65 8488 4 72 250 28 5
67 8504 4 88 250 32 5
69 8512 4 96 250 36 5
71 8528 4 112 250 40 6
73 8584 4 168 250 44 5
75 8644 4 228 250 48 5
Rating List (Best):
Rating = 8606; Shutter = 250; Gain = 48
Rating = 8581; Shutter = 250; Gain = 44
Rating = 8553; Shutter = 250; Gain = 40
Rating = 8527; Shutter = 250; Gain = 36
Rating = 8505; Shutter = 250; Gain = 32
Rating = 8488; Shutter = 250; Gain = 28
Rating = 8476; Shutter = 250; Gain = 24