MS-4 Imager User’s Manual 7-37
I/O Parameters
Print Growth Threshold
Axial Non-Uniformity Threshold
Unused Error Correction Threshold
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity
threshold,output on UEC,UEC threshold>
Default: Grade C
Options: 0 = Grade A
3 = Grade D
1 = Grade B 2 = Grade C
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity
threshold
,output on UEC,UEC threshold>
Default: Grade C
Options: 0 = Grade A
3 = Grade D
1 = Grade B 2 = Grade C
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity
threshold,output on UEC,
UEC threshold
>
Default: Grade C
Options: 0 = Grade A
3 = Grade D
1 = Grade B 2 = Grade C