3-6 MS-4 Imager User’s Manual
Host Port Protocol
Point-to-Point with RTS/CTS and XON/XOFF
ACK/NAK
Polling Mode
Poll Address
Note: See USB HID Interface on page 3-23 for protocol information relating to USB.
Usage: Used only with RS-232.
Definition: This option is a combination of Point-to-Point with RTS/CTS and Point-
to-Point with XON/XOFF.
Serial Cmd: <K140,3>
Definition: See the ACK / NAK Options command <K147> on page 3-7.
Serial Cmd: <K140,4>
Definition: See the Polling Mode Options command <K148> on page 3-8.
Serial Cmd: <K140,5>
Serial Cmd: <K140,protocol,address>
Default: 1
Options: 1 to 50
1 = Poll address 0x1C, Select address 0x1D
2 = Poll address 0x1E, Select address 0x1F
...
50 = Poll address 0x7E, Select address 0x7F