MS-4 Imager User’s Manual 9-7
Matchcode
Sequence on No Read
As an example of Sequence on No Read Enabled, consider the following decodes:
As an example of Sequence on No Read Disabled, consider the following series of
decodes:
Usage: Sequence on No Read is useful when the Imager needs to stay in
sequence even if no decode occurs.
Definition: When Sequence on No Read is Enabled and Matchcode is set to
Sequential, the Imager sequences the master symbol on every match or
No Read. When disabled, it does not sequence on a No Read.
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,
sequence on No Read
,sequence on mismatch>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Master Symbol Decoded Symbol Master Symbol after Decode
001 001 002
002 002 003
003 No Read 004 (sequenced on No Read)
004 004 005
005 No Read 006 (sequenced on No Read)
006 No Read 007 (sequenced on No Read)
007 007 008
Master Symbol Decoded Symbol Master Symbol after Decode
001 001 002
002 002 003
003 No Read 003 (not sequenced)
003 003 004
004 No Read 004 (not sequenced)
004 No Read 004 (not sequenced)
004 004 005
Page view 234