7-22 MS-4 Imager User’s Manual
LED Configuration
LED Configuration
In ISO/IEC 16022 grade mode the LEDs represent the grade of the first Data Matrix
symbol decoded in the read cycle.
The parameter to be graded is set in the ISO/IEC 16022 Grade options.
For example, to program the LEDs to indicate the ISO/IEC 16022 print growth grade, set
LED Mode to ISO/IEC 16022 Grade and set ISO/IEC 16022 Grade to Print Growth. If all
the LEDs from 20% to 100% were illuminated, the read result would be a grade A; if only
the 20% LED were illuminated, the result would be a grade F.
Standard
In Standard Mode, the STATUS LED indicates read cycle status and the GOOD READ
LED illuminates upon a good read at the end of a read cycle. In a read rate test, these
LEDs represent the percentage of good reads per images captured.
ISO/IEC 16022 Grade
Usage: Useful as a visible verification of read rates and symbol quality.
Definition: Determines the mode in which the status LEDs operate.
Serial Cmd: <K737,LED mode,ISO/IEC 16022 grade>
Default: Standard
Options: 0 = Standard 1 = ISO/IEC 16022 grade
Usage: Provides visual grading of specific ISO/IEC 16022-related features.
Definition: Determines which ISO/IEC 16022 feature the Imager will grade via the
LEDs.
Serial Cmd: <K737,LED mode,ISO/IEC 16022 grade>
Default: Final Grade
Options: 0 = Final Grade
3 = Unused ECC
1 = Symbol Contrast 2 = Print Growth