MS-4 Imager User’s Manual 11-7
Configuration Database
Symbology Type
Disabled
When Symbology Type is disabled, the database uses the current Symbology Type
setup to determine active symbologies.
Any Symbology Type (Add 1)
All symbologies are enabled while this database index is being used.
Data Matrix (Add 2)
If enabled, Data Matrix will be active for this database index.
Important: The ECC level must be configured using the Data Matrix command <K479>. If
no ECC level has been configured, the Imager will not decode Data Matrix symbols.
QR Code (Add 4)
If enabled, QR Code will be active for this database index.
Code 128 (Add 8)
If enabled, Code 128 will be active for this database index.
Code 39 (Add 16)
If enabled, Code 39 will be active for this database index.
Codabar (Add 32)
If enabled, Codabar will be active for this database index.
Definition:
This field allows the user to configure the database to enable specific symbologies
for selected database indexes. Symbology-specific parameters must be
configured with the appropriate symbology command.
For example, if fixed length Code 128 is required, it must first be set up with
the Code 128 command:
<K474>
.
To select a particular symbology, just add the number value associated with
that symbology type.
Examples:
If Data Matrix and Code 39 are required, the paramater would be: 2 + 16 =
18
.
If I 2/5, BC412, and DataBar Limited are required, the parameter would be:
128 + 2048 + 16384 =
18560
.
Serial Cmd: <K255,index,shutter speed,gain,sub-sampling,row pointer,column
pointer,row depth,column width,threshold mode,fixed threshold value,processing
mode,narrow margins,background color,symbology type>