Microscan MS-4X User Manual Page 102

  • Download
  • Add to my manuals
  • Print
  • Page
    / 374
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 101
5-6
MS-4X Imager Us
er Manual
Trigger Mode and Filter Duration
Trigger Mode and Filter Duration
Trigger Mode
Continuous Read
Definition: The Trigger is the event that initiates a read cycle.
Note: When calibrating the imager or testing read rate, the current trigger
setting will be disregarded.
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: Continuous Read
Options: 0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
Usage: Continuous Read is useful in testing symbol readability or reader functions.
It is not recommended for normal operations.
Definition: In Continuous Read, trigger input options are disabled, the imager is
always in the read cycle, and it will attempt to decode and transmit every
capture. If a single symbol stays within read range for multiple read cycles,
its data will be transmitted repeatedly until it leaves the read range.
The imager sends replies to serial commands that require responses when
symbol data is transmitted, or read cycle timeout is enabled and a timeout
occurs and at least one captured image has been processed. Depending
on the combination of enabled symbologies, the imager may take longer
than the timeout to process a captured image.
Note: When to Output
and
No Read
options have no affect on
Continuous
Read.
Serial Cmd: <K200,0>
Page view 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 373 374

Comments to this Manuals

Vikitpm 04 Jan 2024 | 15:20:38

urenrjrjkvnm

Evapsi 07 Jan 2024 | 00:41:38

Med