MS-4X Imager User Manual
3-11
Communications
Parity, Auxiliary Port
Stop Bits, Auxiliary Port
Data Bits, Auxiliary Port
Usage: Only changed if necessary to match host setting.
Definition: An error detection routine in which one data bit in each character is set to 1
or 0 so that the total number of 1 bits in the data field is even or odd.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d.
status,daisy chain i.d.>
Default: None
Options: 0 = None 1 = Even 2 = Odd
Usage: Only changed if necessary to match host setting.
Definition: Allows the user to select the last one or two bits in each character to indicate
the end of the character.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d.
status,daisy chain i.d.>
Default: One
Options: 0 = One 1 = Two
Usage: Only changed if necessary to match host setting.
Definition: Number of bits in each character.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d.
status,daisy chain i.d.>
Default: Eight
Options: 0 = Seven 1 = Eight