MS-4X Imager User Manual
3-3
Communications
Communications Serial Commands
Host Port Connections <K100,baud rate,parity,stop bits,data bits>
Auxiliary Port Connections <K101,aux port mode,baud rate,parity,stop bits,data
bits,daisy chain ID status,daisy chain ID>
RS-422 Status <K102,status>
Host Port Protocol <K140,protocol,address>
Preamble <K141,status,preamble characters>
Postamble <K142,status,postamble characters>
Response Timeout <K143,response timeout>
LRC <K145,status>
Auxiliary Port System Data Status <K146,aux port system data status>
ACK/NAK Options <K147,RES,REQ,STX,ETX,ACK,NAK>
Polling Mode Options <K148,RES,REQ,STX,ETX,ACK,NAK>
Autoconfiguration Daisy Chain <K150DAISY>